SIGN | ALARM CAUSE | SOLUTION |
---|---|---|
Err0 | Weighing Signal Type Error. | Power-on again after making sure that the set value of parameter [111] ‘Weighing Signal Type’ and the switch position of DIP1/DIP2 are matched with the actual weighing input signal. |
Err1 | RAM Failure. | Replace the chip RAM. |
Err2.1 Err2.2 |
EEPROM Failure. | Replace the chip EEPROM. |
Err3 | Unused. | |
Err4 | ADC Failure. | Replace the ADC module. |
oV-Ad | Over ADC Range. |
Weighing signal exceeds A/D conversion range. 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
oL | Overload Alarm. |
Gross Weight > (Scale Capacity + 9 × Scale Division). 1. Check if the loadcell is connected. 2. Check if the capacity of loadcell is too small. 3. Check if the loading weight is too big. |
oV-tr | Not meet the condition of Maunal Tare. | When Gross Weight is at the state with negative value display, overload alarm or dynamic variation, ‘Manual Tare’ will be invalid. |
oV-nZ | Over ‘Manual/Auto Zero Limit’. | Refer to parameter [123] ‘Manual/Auto Zero Limit’. |
tXX.XX | Preheating Time Countdown [min.sec]. |
Refer to parameter [128] ‘Zero Upon Power Up’, [129] ‘Power Up Zero Time’ and [130] ‘Power Up Zero Limit’. |
oV-Zr | Over ‘Power Up Zero Limit’. | Wait for the preheating time over or press any key to exit. |